BLRBC - MS-185 FREON TA SOLVENT

  • MSDS: BLRBC
  • Manufacturer: MILLER STEPHENSON
  • Product Name: MS-185 FREON TA SOLVENT
  • National Stock Number: 6850-00F019804
Product Identification

Product ID:MS-185 FREON TA SOLVENT
MSDS Date:01/01/1987
FSC:6850
NIIN:00F019804
MSDS Number: BLRBC

Responsible Party
MILLER-STEPHENSON
GEORGE WASHINGTON HIGHWAY
DANBURY 06810

Emergency Phone: (203) 797-2212

Info Phone: (203) 797-2212

Cage: 18598

Contractor
MILLER-STEPHENSON CHEMICAL CO INC
950 DANBURY, CT 06810 US

Telephone: 203-743-4447

Cage: 18598

Ingredients

ACETONE (SARA III)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 9%

OSHA PEL 1000PPM

ACGIH TLV: 750PPM/1000STEL;9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


TRICHLOROTRIFLUOROETHANE (FREON TF)

CAS: 354-58-5

RTECS: KJ3975000

Fraction By Weight: 71%


DICHLORODIFLUOROMETHANE (SARA III)

CAS: 75-71-8

RTECS: PA8200000

Fraction By Weight: 20%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:ORAL LD50 (RATS): 9,750 MG/KG. ACETONE
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: SUFFOCATION,
LIGHT-HEADEDNESS, GIDDINESS, SHORTNESS OF BREATH, NARCOSIS, CARDIC
IRREGULARITIES, UNCONSCIOUSNESS, OR DEATH. SKIN: DEFATTING CAUSING
IRRITATION. EYES: IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: SUFFOCATION, LIGHT-HEADEDNESS,
GIDDINESS, SHORTNESS OF BREATH, NARCOSIS, CARDIAC IRREGULARITIES,
UNCONSCIOUSNESS, OR DEATH. SKIN: DEFATTING CAUSING IRRITATION.
EYES: IRRITATION.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. IF BREATHING STOPS, GIVE
CPR, PREFERABLY MOUTH-TO-MOUTH. IF BREATHING IS DIFFICULT, GIVE
OXYGEN. DON'T GIVE EPINEPHRINE/SIMILAR DRUGS. EYES/SKIN: FLUSH
W/PLENTY OF WAT ER FOR AT LEAST 15 MINS. INGESTION: DON'T INDUCE
VOMITING. ASPIRATION INTO LUNGS IS >HAZARD THAN ALLOWING IT TO
PROGRESS THROUGH THE INTESTINAL TRACT. OBTAIN MEDICAL ATTENTION IN
ALL CASES. SEE SUPP.

Fire Fighting

Flash Point Method:TOC
Extinguishing Media:NON-FLAMMABLE
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS.
ADDITION OF EXCESS WATER (>0.2%) WILL EXTRACT ACETONE & MAY FORM A
FLAMMABLE/SUPERNANAT LIQUID LAYER.
Unusual Fire/Explosion Hazard:AT ELEVATED TEMPERAURES, PRESSURIZED
AEROSOL CONTAINERS MAY VENT/RUPTURE/BURST & ADD TO FLYING/FALLING
DEBRIS.

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
ALLOW TO EVAPORATE.

Handling

Handling and Storage Precautions:DON'T STORE NEAR HEAT SOURCES, IN
DIRECT SUNLIGHT OR TEMPERATURES >120F. DON'T PUNCTURE OR DAMAGE
CONTAINERS.
Other Precautions:ROTATE STOCK TO SHELF LIFE OF ONE YEAR. DON'T SPRAY
ON SKIN. AVOID BREATHING VAPORS & SKIN EXPOSURE. USE ONLY IN
WELL-VENTIATED AREA.

Exposure Controls

Respiratory Protection:USE SELF-CONTAINED BREATHING APPARATUS.
Ventilation:NORMAL OR LOCAL EXHAUST, MECHANICAL IN LOW PLACES
Protective Gloves:BUTYL
Eye Protection:CHEMICAL SPLASH GOGGLES
Supplemental Safety and Health
FIRST AID (CONT'D), NOTE TO PHYSICIAN: BECAUSE OF POSSIBLE INCREASED
RISK OF ELICITING CARDIAC DYSRYTHMIAS, CATECHOLAMINE DRUGS, SUCH AS
EPINEPHRINE, SHOULD BE CONSIDERED ONLY AS A LAST RESORT IN LIFE
THREATENING EMERGENCIES.

Chemical Properties

Boiling Pt:B.P. Text:110.5F
Vapor Pres:380
Vapor Density:2.6
pH:7
Evaporation Rate & Reference:(CCL4 = 1): 0.3
Solubility in Water:SLIGHT
Appearance and Odor:CLEAR COLORLESS LIQUID W/FAINT SOLVENT ODOR
Percent Volatiles by Volume:100%

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:OPEN FLAME, HIGH TEMPERATURES, GLOWING/RED
HOT METAL SURFACES, SUNLIGHT, TEMPERATURES >120F, & OTHER SOURCES
OF IGNITION
Hazardous Decomposition Products:HYDROCHLORIC, HYDROFLUORIC ACIDS, &
POSSIBLE CARBONYL HALIDES

Disposal

Waste Disposal Methods:ALLOW TO EVAPORATE. DON'T PUNCTURE OR INCINERATE
AEROSOL CANS. LANDFILL ACCORDING TO FEDERAL, STATE, & LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.